Global Insight

Introducing a new addition to the Optimum family of materials

The Optimum range of materials has become established as one of the most popular RGP materials on the market. Recent years have seen remarkable growth in the usage of both ortho-k and scleral lens usage and, in response to this Contamac have developed Optimum Infinite, a hyper-Dk material which cuts like a regular material and wets without the need for plasma or surface coating. The material has a Dk of 180 yet, unlike other high Dk materials, does not flex, making it ideally suitable for both scleral and overnight wear ortho-k use.

It is also useful for high oxygen demand corneae, such as in the case below kindly submitted by Michael Wyss of Eyeness AG, Switzerland.

Patient 

MB Male, aged 64 years

Medical History

Chronic Sarcoidosis and Rheumatoid Arthritis, Glaucoma. RE AMD (no usable vision).

Handling issues because of arthritis – extended wear RGP lens worn LE only.

Spectacles 

BCVA with specs 0.5 LE

Contact Lenses 

BCVA with Cl 1.0 LE (-3.00)

Hypoxia-related problems including corneal edema and endothelial blebs with current lens (Dk 125) reduced comfort and visual acuity.

BCVA with Cl reduced to L 0.2.

Topography 

Optimum Infinite CS - Oculus reading
Left eye topography showing distortion

Contact Lenses

Original L Lens + Fl

Same lens design but in Optimum Infinite

Edema and distortion reduced, visual acuity improved to 1.0, extended wear now resumed up to 1 week.